PHD-4
|
| |
 |
| |
Features and Benefi
|
| |
 |
| High Sensitivity to Helium -
Can detect very small leaks
|
| 
|
High Sensitivity (2 ppm) to helium, three orders of magnitude better than industry standard,
|
| 
|
due to SIPD (proprietary and patented Selective Ion Pump Detection)
|
| 
|
Excellent selectivity for helium allows you to read helium leaks and ignore all other gases
|
| 
|
Helium sensitivity can be adjusted as required to minimize test costs and helium consumption
|
| 
|
Autozero function allows leak detection even in high helium background environment
|
|
|
| |
 |
| Easy to Use -
No training required
|
|

|
State-of-the-art microprocessor
control allows great simplicity of operation
|
|

|
Fully automatic start-up
|
|

|
Ready for test in less than 3 minutes
|
|

|
ntuitive touch screen display
|
|

|
Visual and audio indicators (standard headphone connection)
|
|
|
No tuning
required
|
|
|
| |
 |
| Truly Portable -
Compact and light |
|

|
The PHD-4 weighs only 2,6 Kg (5.7
lbs) including the battery |
|

|
Its compact size allows it to be easily carried
anywhere* Its ergonomic design allows |
|

|
comfortable use for extended periods |
|
|
| |
 |
| Versatile -
Suitable for many different applications |
|

|
Wide range of
uses: replaces or can be used with existing methods such as |
|
|
bubble test or
pressure decay |
|

|
Able to detect both very small and large leaks |
| 
|
Can
operate either on battery power or connected to an outlet |
| 
|
Displayed
messages can be viewed in several languages (English, French, German, Italian) |
| 
|
Standard Analog and RS232 Serial output. |
|
|
| |
 |
| Dependable -
Long term operation
|
|

|
Automatic backflow valve prevents
helium saturation,
|
|
|
ensuring fast response times as well as long life of sensing
element.
|
|

|
CE, CSA/US approved for global standardization.
|
|
|
| |
The New PHD- 4 Portable Helium Detector
|
| |
 |
| |
Technical Specifications
|
| |
|
|
Lowest Detectable Helium Concentration :
|
|
2 ppm (parts per million)
|
|
|
Lowest Detectable Helium leak :
|
|
5 x 10-6 mbar l/s
|
|
|
|
|
5 x 10-6 atm cc/s
|
|
|
|
|
5 x 10-7 Pa
m3/s
|
|
|
Response Time :
|
|
< 2 sec
|
|
|
Response Time :
|
|
<10 sec (from 50 ppm to 0 ppm)
|
|
|
Start up time, including self check-up :
|
|
3 min approx.
|
|
|
Power Supply :
|
|
* 12 Vdc, 1.2 A Rechargeable Battery included
|
|
|
|
|
* 110-240 V
50-60 Hz Transformer/
|
| |
|
|
Battery Charger included
|
|
|
Battery operation Time :
|
|
4 hours
|
|
|
Maximum Signal Drift :
|
|
10 ppm/10 min
|
|
|
Operating Conditions Temperature :
|
|
+5°C to +35°C
|
|
|
Humidity :
|
|
90% maximum relative humidity
|
|
|
Storage
Conditions Temperature :
|
|
-20°C to +60°C
|
|
|
Weight :
|
|
2,6 Kg (5.7 lbs)
|
|
|
Compliance to Norms :
|
|
CE approved CSA/US approved
|
|
|
| |
Ordering Information
|
| |
|
|
PHD-4 Complete Package
|
|
Part Number
|
|
|
Travel Case includes
|
|
9694640
|
|
|
* PHD-4 Basic Unit
|
|
|
|
|
* Spare Battery
|
|
|
|
|
* Transformer/Battery Charger (110-240V)
|
|
|
|
|
* Carrying Strap
|
|
|
|
|
* Probe
Set
|
|
|
|
|
* 15-pin I/O connector
|
|
|
|
|
* CD Instruction Manual
|
|
|
|
|
PHD-4 Replacement Part Kit
|
|
Part Number
|
|
|
Includes
|
|
9694660
|
|
|
* Sampling Pump with Fittings
|
|
|
|
|
* Probe with
Sampling Line
|
|
|
|
|
* Tip Probe Filter
|
|
|
|
|
* Internal Filter (Kit of 5
units)l
|
|
|
|
|
PHD-4 Basic Package
|
|
Part Number
|
|
|
Includes
|
|
9694600
|
|
|
* PHD-4 Basic Unit
|
|
|
|
|
* Transformer/Battery
Charger (110-240V)
|
|
|
|
|
* Carrying Strap
|
|
|
|
|
* 15-pin I/O connector
|
|
|
|
|
* CD
Instruction Manual
|
|
|
|
|
Accessories
|
|
Part Number
|
|
|
* Probe Set
|
|
9693515
|
|
|
* Capillary leak with refillable reservoir and
gauge
|
|
9693540
|
|
|
* Probe with 10 meter (30') maximum Sampling Line
|
|
9693525
|
|
|
* Telescoping
Extension Probe
|
|
9693520
|
|
|
Individual Replacement Parts
|
|
Part Number
|
|
|
|
|
SR 03.702609
|
|
|
* Spare Battery
|
|
SR 03.702888
|
|
|
* Transformer/Battery Charger (110-240V)
|
|
SR 03.702513
|
|
|
*
Sampling Pump with Fittings
|
|
SR 03.702538
|
|
|
* Probe with Sampling Line
|
|
SR 27.590006-01
|
|
|
* Tip Probe
Filter
|
|
SR 28.900012-01
|
|
|
* Internal Filter (Kit of 5 units)
|
|
SR 03.702791
|
|
|
* Carrying Strap* 15-pin I/O
connector
|
|
SR 03.702894
|
|
|
* Travel Case
|
|
SR
03.702890
|
|
|
| |
Applications
|
| |
 |
Large Vessels and Bioreactors
The PHD-4
offers unmatched accuracy and repeatability, presenting a unique solution that
it is cost effective and very well suited for the leak range specifications of
this application. Biotech and pharmaceutical industries used to rely on pressure
decay and bubble test methods for finding leaks in their large bioreactors. The
PHD-4 has established a new standard of quality, significantly increasing
production yields.
* Fermenters * Sterilizers * Freeze
Dryers
|
|
| |
 |
Underground Pipes and Storage Tanks
The
portability and light weight of the PHD-4 plays a major role in this
application. Underground pipes and storage tanks (UST) are slightly pressurized
with helium which, due to its high mobility, can escape through small leaks and
migrate to the surface, where it can be easily detected by the PHD-4. The
accuracy, portability and light weight of this unit greatly simplifies this
process, particularly in difficult construction sites or rough terrain.
*
Gas distribution lines * Under and above ground containers and storage
tanks * Telecommunication and high voltage underground cables
|
|
| |
 |
Water Heating and Cooling Pipes
The PHD-4
allows leak location without interruption of the normal operation, by mixing
helium with the water in the circuit. Until recently, the precise and rapid
location of leaks in buried pipes has been very difficult.In the event of a
leak, helium desorbs from the fluid and diffuses to the surface, where it is
easily detected. Leaks in pipeline systems such as district heating systems,
drinking or chilled water systems and steam pipe networks incur high costs due
to losses and corrosion damage.
* Heater exchangers and steam
condensation lines * Water pipes * Radiant heating systems * Brine
pipes
|
|
| |
 |
Airplane Fuel Tanks and Lines
PHD-4
technology is approved worldwide by airplane manufacturers and operators as the
standard for the location of leaks in aircraft fuel tanks and in oxygen
distribution lines. For this purpose, helium is injected from the outside into
the tank to be checked and the helium probe is used inside the wings to locate
any leaks.
* Fuel tanks * Oxygen distribution lines
|
|
| |
 |
Other Applications
The PHD-4 is in daily
use in many other applications. Virtually any object requiring any level of leak
tightness can be simply tested with this instrument. Here is a partial list of
other applications:
*Components and systems for the Chemical and
Petrochemical Industries * Components for the Automotive industry *
Process gas delivery lines in Semiconductor fabrication industry
|
|
| |
|